Airlock Clearing, Shower Booster Pumps & Heating Pumps in Sligo

After an Uisce Éireann water mains outage, a drained attic tank, or a cylinder repair, pockets of air trapped in low-pressure gravity pipes can completely stop water reaching your hot taps, electric shower, or upstairs radiators. We clear plumbing and heating airlocks and repair or replace faulty shower and heating pumps across Sligo.

€95–€145Clear hot/cold tap or gravity shower airlock
€185–€275Supply & fit new central heating circulating pump
€140–€220Shower booster pump repair / capacitor / replacement
Same VisitMains-pressure back-flushing clears stubborn airlocks

Airlock & Pump Callout Prices in Sligo

Typical prices for resolving water pressure, airlock, and pump faults in Sligo homes:

Pump / Airlock JobTypical Price (incl. VAT)What We Do
Clear Airlocked Hot Water Taps / Gravity Tank Feed€95 – €145Use controlled mains back-pressure / wet-vac extraction to purge trapped air pockets
Bleed & Balance Airlocked Central Heating Radiators€110 – €165Purge air from high-point pipes, bleed all rads, balance lockshield valves & re-pressurise
Replace Central Heating Circulating Pump (6m Head)€185 – €275Isolate pump valves, fit new A-rated Grundfos/Wilo 130mm pump, bleed system
Repair or Replace Twin-Impeller Shower Pump (Hot Press)€140 – €240 (labour + parts)Test reed flow switches/PCB/capacitor or fit new brass/regenerative booster pump

Why Sligo Gravity Hot Water Systems Airlock After a Mains Shut-Off

In most Irish houses built before 2012, the cold kitchen tap is on high mains pressure (2 to 4 bar), while the hot water cylinder and bathroom taps are fed by gravity from the attic tank (only 0.2 to 0.4 bar of head pressure). If the attic ballcock sticks or a mains outage empties the tank, air enters the 22mm drop pipe from the attic. When the tank refills, 0.2 bar of water pressure isn't strong enough to push the buoyant air bubble down around horizontal pipe bends under the floorboards — leaving your hot tapsbone dry until purged professionally.

Frequently Asked Questions: Airlocks & Shower Pumps

Why is my Triton T90SR electric shower humming with the 'Low Pressure' light on?

The Triton T90SR is a tank-fed pumped electric shower fed from your attic tank. If the attic tank ran low or the inline gauze filter inside the shower inlet is blocked with grit, an airlock forms in the feed pipe. Do not run the shower dry — bleeding the inlet and cleaning the gauze filter restores flow in minutes.

Why is my hot-press shower booster pump pulsing on and off by itself in the middle of the night?

When a positive/negative head booster pump pulses for 2 seconds every hour, pressure is slowly dropping on the outlet side — usually because a toilet fill valve, mixer tap cartridge, or non-return check valve is weeping slightly.

Half my radiators are roasting hot and the other half are ice cold — is it the pump?

If downstairs radiators are cold while upstairs radiators are hot, the circulating pump is weak or failing. If one single radiator is cold at the top and warm at the bottom, it simply needs bleeding; if it is cold at the bottom with sludge, the lockshield valves need balancing or flushing.

Do you fit brass-bodied Stuart Turner Monsoon pumps in Sligo?

Yes — we supply, repair, and fit Stuart Turner Monsoon, Techflo, and Salamander twin-impeller and single-impeller pumps.

Request an Immediate Sligo Plumber Callback (Or Call 085 708 8979)

Enter your phone number and town in Co. Sligo for an immediate callback, or tap 085 708 8979 to speak directly to Arek right now.